Can I replace a wb27x11212 with a wb27x11213
I believe my microwave blew the wb27x11212 fuse due to the manufacturing shutoff as the microwave was opened before finishing and the shut off, I replaced the main 20v 125amp fuse and it blew the following night. Upon further investigation I found this thermal shutoff fuse has blown, however when searching for the replacement part I was only able to find the wb27x11213. Close but not exact. Would this work? Will I receive future blown fuses if I attempt this repair? Has anyone dealt with this problem? And help is greatly appreciated . Thank you.
Status:
Open Mar 24, 2020 - 08:55 AM
Support
1answer
Answers
Mar 24, 2020 - 12:46 PM
WB27X11213 is the fan cycling thermostat and is normally open at room temperature. WB27x11212 is the safety shutoff and is normally closed at room temperature. They are not interchangeable and are often confused as they are in close proximity to each other.
View More Product Details
View all GE WB27X11212 Microwave Thermostat Questions & Answers